How Much Ton Steam Boiler 31 Feet

Steam Capacity Conversion Table | Industrial Controls

2010-12-13 · Often it is necessary to convert a measure of capacity from one term to another. The conversion table will allow you to quickly convert various measures of capacity. The table and formulas can help you size and pick out components such as condensate pumps and boiler feed pumps. Some additional conversion factors that may prove helpful are shown below.

Get a Quote

Heat Losses From Bare Steel Pipe & Flat Surfaces

2015-5-13 · for 100 lineal feet of pipe per 30 day month with steam in the pipe 24 hours per day. They are based on coal de-livering 13,000 Btu per pound, priced at $7.00 per ton. Labor and boiler room expense are assumed to be $1 .OO per ton additional. Boiler efficiency is as-sumed at 70%. Air temperature is 80°F. EXAMPLE; You wish to know the

Get a Quote

The future of steamships: steam | REB Research Blog

The drying process removes much of the toxic impact of the coal by removing much of the mercury and toxic oxides. Gasification before combustion further reduces these problems, and reduces the tendency to form adhesions on boiler pipes — a bane of old-fashioned steam power.

Get a Quote

Steam Accumulator Sizing - Boiler and Pressure Vessel

2002-3-31 · Spirax-Sarco's excellent steam handbook, as well as many texts/design guides on boiler sizing provide guidance/rules for determining required water surface area for accumulators & steam drums. A wet accumulator is just a steam drum without the fired energy input: think of it as an extension of the steam drum. Questions:

Get a Quote

How much PSI for my boiler? | Terry Love Plumbing

2017-10-3 · The standard setting is 12 lbs cold. 1 PSI will raise water in a column 2.31 feet. The pressure should be set to what is required in total height of system. For example, if a boiler is in the basement, and its a 2 story house with baseboard radiation on the second floor, it could be 8' + 9' + 1' = 18' (boiler to upper baseboard). 1 PSI / 2.31

Get a Quote

Steam Tables Pressure vs Temperature - Valvesonline

Steam Tables Steam and temperature posess a reliable realtionship whereby if the pressure of the steam is know its temperature can be predicted (and vice versa). Below is a graph and table of this relationship.

Get a Quote

Sizing Steam Pipes (lb/h) - Engineering ToolBox

2020-10-30 · Recommended Velocities in Steam Systems - The steam velocity in a steam distribution system should be within certain limits to avoid excessive wear and tear Sizing Steam Pipes (kg/h) - Steam is a compressible gas where pipe line mass flow capacity depends on steam pressure.

Get a Quote

Air Volume Requirement - Prokup Media

2016-11-11 · Multiply the cubic feet of gas burned per hour by the heat content value obtained from the gas supplier. (1050 BTU default average) The answer is BTUH INPUT to the furnace. For example, lets say we timed 36 seconds per revolution on a 1 Cu. Ft. dial, the furnace is an 80% furnace. 36 seconds = 200 cubic feet per hour/2

Get a Quote

Steam—chapter_efficiency

2007-9-18 · In a single boiler it may be accomplished by discharging steam through a waste pipe and regulating the amount by means of a valve. In a battery of boilers, in which only one is tested, the draft may be regulated on the remaining boilers to meet the varying demands for steam, leaving the test boiler to work under a steady rate of evaporation. 6.

Get a Quote

WOODY BIOMASS DEFINITIONS AND CONVERSION

2007-12-13 · Green Ton (GT) = 2,000 lbs of fresh cut woody material at a "green" moisture content = 200 cubic feet (a.k.a 1 unit of chips) 1 ccf (hundred cubic feet) roundwood = 1.0 BDU chips • 1 BDT burned in a typical commercial boiler fuel will produce 10,000 lbs. of steam • 10,000 lbs. of steam will produce about 1,000 horsepower or

Get a Quote

Steam Tables - Missouri

steam table. Total Heat of Steam (Column 6). The sum of the Heat of the Liquid (Column 4) and Latent Heat (Column 5) in Btu. It is the total heat in steam above 32°F. Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound. Specific Volume of Steam (Column 8). The volume per unit of mass in cubic feet per pound.

Get a Quote

Steam—chapter_chimneys

2007-9-18 · Losses in Flues —The loss of draft in straight flues due to friction and inertia can be calculated approximately from formula (), which was given for loss in stacks.It is to be borne in mind that C in this formula is the actual perimeter of the flue and is least, relative to the cross sectional area, when the section is a circle, is greater for a square section, and greatest for a

Get a Quote

The Yorkshire Patent Steam Wagon Company. | 7th

Exhibit:6-ton Wagon with Vertical Engine. This new-type 6-ton wagon has been designed to come within the requirements of the Local Government Board, and to deal with a total useful load of to tons, divided between the wagon-body (6 tons) and a single trailer (4 tons), along a good macadam or paved road, and up gradients of i in to.

Get a Quote

Steam Calculators: Boiler Calculator

Steam, Boiler, and Blowdown Pressure are the same. Combustion Efficiency is the % of fuel energy that is directly added to the feedwater and not otherwise lost or used. Blowdown Rate is the % of incoming feedwater mass flow rate that leaves the boiler as a saturated liquid at boiler pressure.

Get a Quote

Greenhouse Gases Equivalencies Calculator -

0.1 mmbtu/1 therm × 14.43 kg C/mmbtu × 44 kg CO 2 /12 kg C × 1 metric ton/1,000 kg = 0.0053 metric tons CO 2 /therm. Carbon dioxide emissions per therm can be converted to carbon dioxide emissions per thousand cubic feet (Mcf) using the average heat content of

Get a Quote

TECHNICAL CALCULATION AND ESTIMATOR'S MAN

2013-11-12 · Thank you for showing interest in buying our book TECHNICAL CALCULATION AND ESTIMATOR'S MANHOURS MANUAL You can buy the electronic v ersion of the Manual containing all the figurest and other relat ed data at the

Get a Quote

What is APH in a boiler? - Quora

APH is air pre heater it is a lagre circular rotating heater it can raise boiler efficiency about 1% for every 40F in temperature increase. The most common way to preheat the air is with a heat exchanger on the flue exhaust. The basic component of

Get a Quote

Calculate the LPG Consumption per Hour by Burner

2020-10-31 · Last Updated: 14 October 2019 Calculate the LPG (Propane) Consumption per Hour by Burner Size - Propane Gas Consumption A gallon of propane contains 91,502 BTU of heat energy whilst the BTU rating for appliances is in BTU per hour, based on burner size.

Get a Quote

BLOWDOWN CALCULATION FOR BOILER - Altret

2019-4-17 · steam can occur. To prevent boiler tube chocking and overheating of the boiler tubes the blow down is necessary. The blow down is the water removed from boiler to maintain the solids level in the boiler drum. This can be calculated as follows: E = Evaporation or steam generation rate. S = Amount of solids (ppm) B = Blow down (m3 / hr)

Get a Quote

Steam generator part 1 - SlideShare

Nuclear Steam Generating Systems In commercial power plants steam generators can measure up to 70 feet (~21m) in height and weigh as much as 800 tons. Each steam generator can contain anywhere from 3,000 to 16,000 tubes, each about three-quarters of an inch (~19mm) in diameter.

Get a Quote

2020 Boiler Costs | Installation & Replacement Cost

New Boiler Costs. Installing a new boiler costs $5,663 on average with a typical range between $3,619 and $8,018.A standard efficiency model (80%-89% AFUE) runs an average of $3,000 to $6,000. High efficiency models (90%+ AFUE) cost $6,000 to $11,000. Of that, labor costs $1,000 to $2,500.The main cost factors you'll need to consider include brand, BTU needs, type of boiler and what you can

Get a Quote

How much coal is required to generate 1 ton of steam

As a rule of thumb you would need about 138 Kg of coal (26GJ/Ton) to produce 1 ton of steam.

Get a Quote

Tips for a Successful Steam Boiler Replacement | U.S

Heat boiler up. Avoid making steam. Skim the boiler. For directions on proper skimming, read my Beck Tips in the US Boiler Report from July 2015. Adjust your pressure control to proper settings. Cut-out should normally be 2 PSI or less. Cut-in should normally be a ½ PSI or less. Some steam boilers use controls that measure pressure in ounces.

Get a Quote

cost of steam generators 25 mmbtu - ingenieurbuero

PROJECT DETAIL. Product:cost of steam generators 25 mmbtu Standard: ASME, ISO,IBR Packaging Detail: Regular packing or nude packing, or upon customers requirement. Transportation: by land or by sea, depended on the exporting area; Email: [email protected] Inquiry Now

Get a Quote

Pipe Sizing Steam Supply andCondensateReturn Lines

2006-12-6 · Assume a boiler operates at a steam pressure of 15 psig and is supplying a 300-ton steam absorption machine which requires a minimum operating pressure of 12 psig. There is a 2 psig pressure drop along the steam mains and the absorption machine is rated to condense 6,000 lbs/hr. The branch line is 50 feet long and has three standard elbows plus

Get a Quote

Boiler Hp To Ton -coal fired boiler - myappsun.de

Industrial Boiler Companies And Suppliers Energy Xprt; Fire Tube Structure Oil Fired Thermal Oil Boiler Price; Gas Steam Boiler mdboilers; Calcutta Traveling Grate Steam Boiler Chandigarh; Steam Boiler Agent Compact Usa Made 1200 Kilos Hour; Bath Center Oil Boiler Manufacturers; 12 Bars Fir Tube Boiler In Textile Factory; Household Heating

Get a Quote

How to Calculate Gas Consumption in a - ZG steam

2020-7-27 · We have over 70 years' experience of industrial steam boiler and autoclave, and we have a professional installation and after-sales staff for products.Take advantage of the most economical way to improve efficiency and operating flexibility, Get substantial savings on your fuel costs,Reduce all emissions for each K/W of electricity generated

Get a Quote

BLOWDOWN CALCULATION FOR BOILER - Altret

2019-4-17 · steam can occur. To prevent boiler tube chocking and overheating of the boiler tubes the blow down is necessary. The blow down is the water removed from boiler to maintain the solids level in the boiler drum. This can be calculated as follows: E = Evaporation or steam generation rate. S = Amount of solids (ppm) B = Blow down (m3 / hr)

Get a Quote

Heat Losses From Bare Steel Pipe & Flat Surfaces

2015-5-13 · for 100 lineal feet of pipe per 30 day month with steam in the pipe 24 hours per day. They are based on coal de-livering 13,000 Btu per pound, priced at $7.00 per ton. Labor and boiler room expense are assumed to be $1 .OO per ton additional. Boiler efficiency is as-sumed at 70%. Air temperature is 80°F. EXAMPLE; You wish to know the

Get a Quote

Coal Used in Steamships - 1887 | GG Archives

2020-10-26 · This would be 50 feet longer than the Etruria, and 5 feet broader. His ideal is one of much greater breadth, say 75 feet; but there is a difficulty in the way of docking a vessel of such extreme width. That such a ship will pay as well as those now afloat can hardly be questioned.

Get a Quote

1 tph steam boiler heating surface area to calculate –

Boiler Calculations surfaces in the boiler: drawing the steam heating Detailed p-h diagram of the PCF boiler steam/water heating process (red line) 2013-9-12 · Richard: Heating surface area of a boiler is usually expressed in square feet (12" x 12" = 144" or 1 sq.

Get a Quote

Pumps Selection & Sizing - Industrial steam

2020-10-31 · The objective when sizing boiler feed pumps is to find the pump which will operate under the conditions required. The pump selection should consider first cost, reliability and electrical consumption. There are seven steps involved in pump selection. 1. Determine the number of pumps required 2. Determine if modulating feedwater or on-off feedwater control will []

Get a Quote

United States Natural Gas Industrial Price (Dollars per

2020-10-30 · Release Date: 10/30/2020: Next Release Date: 11/30/2020: Referring Pages: Natural Gas Industrial Price ; U.S. Natural Gas Prices; Natural Gas Industrial Price

Get a Quote

How much PSI for my boiler? | Terry Love Plumbing

2017-10-3 · The standard setting is 12 lbs cold. 1 PSI will raise water in a column 2.31 feet. The pressure should be set to what is required in total height of system. For example, if a boiler is in the basement, and its a 2 story house with baseboard radiation on the second floor, it could be 8' + 9' + 1' = 18' (boiler to upper baseboard). 1 PSI / 2.31

Get a Quote

RULES AND REGULATIONS FOR BOILER AND PRESSURE

2019-12-23 · (c) Heating Boiler - A steam or vapor boiler operating at a pressure not exceeding l5 psi steam pressure or a hot water boiler in which water or other fluid is heated and intended for operation at pressures not exceeding l60 psi or temperatures not exceeding 250 degrees Fahrenheit. (d) Electric Boiler - A power boiler or heating boiler

Get a Quote

Conversion Factors - HeatingHelp.com

2014-6-17 · EDR to Grate Area in Square Feet (Divide EDR by 196) • BTUH to EDR (Divide BTUH by 240) BTUH to Boiler Horsepower (Divide BTUH by 33,475) • PSIG to Feet of Water (Multiply PSIG by 2.31) Boiler Horsepower to Pounds of Condensate per hour (Multiply BHP by 34.5) • Boiler steaming rate (regardless of type or manufacturer) = 1/2 GPM per 1,000

Get a Quote

10 ton steam boiler equals to how much heating

how much heating surface area of 5 ton boiler 1 tph steam boiler heating surface BHP is equal to 34.5 pph of steam and 0.10 square feet of heat transfer . 1 tph steam boiler heating surface area to how much heating surface area of 1 ton boiler from Heating Surface Area but I need to convert this area . 10 tons steam boiler generate how mw

Get a Quote

Greenhouse Gases Equivalencies Calculator -

0.1 mmbtu/1 therm × 14.43 kg C/mmbtu × 44 kg CO 2 /12 kg C × 1 metric ton/1,000 kg = 0.0053 metric tons CO 2 /therm. Carbon dioxide emissions per therm can be converted to carbon dioxide emissions per thousand cubic feet (Mcf) using the average heat content of

Get a Quote

Pipe Sizing Steam Supply andCondensateReturn Lines

2006-12-6 · Assume a boiler operates at a steam pressure of 15 psig and is supplying a 300-ton steam absorption machine which requires a minimum operating pressure of 12 psig. There is a 2 psig pressure drop along the steam mains and the absorption machine is rated to condense 6,000 lbs/hr. The branch line is 50 feet long and has three standard elbows plus

Get a Quote

Miscellaneous Industrial Costs - Michigan

2016-2-25 · BOILER RATINGS Packaged boilers are rated on the basis of maximum continuous nozzle output, in terms of boiler horsepower, B.T.U. per hour, or pounds of steam per hour at 212° F. Available information can be converted to horsepower by using the table below. 1 boiler horsepower = 33,500 B.T.U. per hour = 139 square feet of steam radiation

Get a Quote

How much natural gas is required to produce 1 ton of

It depends on pressure and degree of super-heat. But if speaking of saturated steam at 212 degrees F. starting from water, also at 212 degrees F. and your ton is a standard US Ton of 2,000 lbs. mass, and a boiler at 85% thermal efficiency: 2000 x

Get a Quote

Boiler horsepower to kilowatts [BHP to kW]

How to convert boiler horsepower to kilowatts [BHP to kW]:. P kW = 9.81055407 × P BHP. How many kilowatts in a boiler horsepower: If P BHP = 1 then P kW = 9.81055407 × 1 = 9.81055407 kW. How many kilowatts in 39 boiler horsepower: If P BHP = 39 then P kW = 9.81055407 × 39 = 382.61160873 kW. Note: Boiler horsepower is an imperial or United States customary unit of power.

Get a Quote

Steam—chapter_efficiency

2007-9-18 · In a single boiler it may be accomplished by discharging steam through a waste pipe and regulating the amount by means of a valve. In a battery of boilers, in which only one is tested, the draft may be regulated on the remaining boilers to meet the varying demands for steam, leaving the test boiler to work under a steady rate of evaporation. 6.

Get a Quote

Conversion Tables, Formulas and Suggested Guidelines

2013-11-22 · Table 8. Fertilizer conversions for specified square feet and row area FER TI LIZE R RATE FOR SPECIFIC AREAS MATERIAL GROUPED BY APPROXIM ATE WEIGHT PER PINT Per 10 feet of row spaced** Recommended rate per acre* lb 100 sq ft lb 10 00 sq ft lb 10 sq ft tbs 100 sq ft pt 1 ft tbs 2 ft tbs 3 ft cup 10 oz per pint Sulfur or 100 0.2 2.3 1.2 0.4 1.2

Get a Quote

2020 Boiler Costs | Installation & Replacement Cost

New Boiler Costs. Installing a new boiler costs $5,663 on average with a typical range between $3,619 and $8,018.A standard efficiency model (80%-89% AFUE) runs an average of $3,000 to $6,000. High efficiency models (90%+ AFUE) cost $6,000 to $11,000. Of that, labor costs $1,000 to $2,500.The main cost factors you'll need to consider include brand, BTU needs, type of boiler and what you can

Get a Quote

Steam Tables Pressure vs Temperature - Valvesonline

Steam Tables Steam and temperature posess a reliable realtionship whereby if the pressure of the steam is know its temperature can be predicted (and vice versa). Below is a graph and table of this relationship.

Get a Quote

Steam per cubic ft of natural gas - Heat Transfer

2009-1-17 · My steam tables say that you need to add 886 BTU/lbm to change water at 105 psia to steam. Natural gas is somewhere around 1,000 BTU/ft^3. If you made 618,018 lbm of steam then 59 MCF/day just ain't reasonable. I've seen a bunch of gas bills that reported numbers in hundreds of MBTU's. Your problem has to be a slipped decimal.

Get a Quote

HVAC Rule of Thumb Calculator - Engineering Pro Guides

2018-9-6 · much better with water due to its increased heat capacity. EER: The Energy Efficiency Ratio or EER is the ratio of the total cooling Btu/h to the total input power in watts. The conversion from EER to kW/ton is shown below. 1 ' ' 4 L 1 $ P Q D 1 9 = P P ∗ 1 P K J 12,000 $ P Q D ∗ 1 0.001 L 1 P K J 12 G 9

Get a Quote

boiler for dry steam room - lestagioni.de

Steamist Steam Bath Generators & Steam Room Boilers. Steamist steam shower boilers are engineered for commercial club steam rooms with dimensions between 40 to 2,000 cubic feet. Health club facility managers should choose a steam shower boiler unit with a power rating that is suitable for their steam

Get a Quote

Weil-McLain 381357806 CGa-5-PIDN - 117K BTU -

2015-10-29 · Buy Weil-McLain 381357806 Today. Free Shipping. Check the Weil-McLain CGa-5-PIDN - 117K BTU - 83.5% AFUE - Hot Water Gas Boiler - Chimney Vent ratings before checking out.

Get a Quote